4.10 Alarm Message
If a malfunction occurs in the machine an alarm
message appears in the display and an audio signal
is heard at the same time (rapid-interval horn sound).
Description, possible cause and remedy are shown in
Chapter 4.11.
All functions of the covered menu are
still active.
The softkeys hidden by the alarm
message are deactivated.
Stop audio signal:
• Press the key for softkey .
To reset alarm:
• Press the key for softkey . The alarm is
reset and the audio signal stops.
If the malfunction occurs again, the alarm message
will appear again.
To delete an alarm:
The option for deleting the alarm
should only be used in emergency
situations.
• Press the key for softkey and hold it
down 5 seconds. The alarm is deleted.
If the malfunction occurs again, no alarm message
will appear.
The alarm message does not appear when the
malfunction occurs until after the control unit is
turned off and back on.