Terminal – Menus [Medium/Comfort Version Electronics]
237
Pos: 103.310 /Üb erschriften/Übersc hriften 3/A-E /A/Alarme @ 374\mod_144 2493866440_ 78.docx @ 27217 71 @ 3 @ 1
16.15.1 Alarms
Pos: 103.311 /BA/I nfo-Center/ Großpackenpress e/Haupt menüs/Alarmmeldunge n/1) Alarm meldungen Tabell e allgemein A0 1(501) - A14( 514) HS Baurei he @ 374\ mod_1442494258 615_78.doc x @ 2721797 @ @ 1
– The fuse in the job computer is
defective.
– Short circuit at voltage outputs
+12V2FU_L
• Check the connection for short
circuit.
• The fuse regenerates itself after
cooling.
– The fuse in the job computer is
defective.
– Short circuit at voltage outputs
+12V3FU_L
– The job computer is defective.
• Replace the job computer.
– The job computer is defective.
• Contact KRONE customer
service.
– The CAN connection between
the job computer and the
KRONE measurement force
computer (KMV1) is interrupted.
– The CAN wiring is defective.
– The KRONE measurement force
computer is inactive.
• Check the CAN wiring.
• Replace the KRONE
measurement force computer
(KMV1).
– The CAN connection between
the job computer and the
KRONE measurement force
computer (KMV2) is interrupted.
– The CAN wiring is defective.
– The KRONE measurement force
computer is inactive.
• Check the CAN wiring.
• Replace the KRONE
measurement force computer
(KMV2).
– Undervoltage
– Tractor battery is defective.
– Tractor alternator is too weak.
– The 12V supply on the tractor
side is too weak or is not
correctly connected to the
battery.
• Connect the KRONE connector
cable directly to the tractor
battery.