EasyManua.ls Logo

Krone Big Pack 890 XC - Page 467

Krone Big Pack 890 XC
612 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KRONE ISOBUS Terminal 6
ISOBUS Shortcut Button (ISB) 6.1
Supplement to Operating Instructions 150000773_00_en
BiG Pack 1270, BiG Pack 1270 XC, BiG Pack 1290, BiG Pack 1290 HDP, BiG Pack 1290 HDP XC, BiG Pack
1290 XC, BiG Pack 890, BiG Pack 890 XC
23
6 KRONE ISOBUS Terminal
NOTICE
Penetration of water in the terminal could lead to malfunction. As a result, the machine
can no longer be operated safely.
Protect the terminal from water.
If the machine is not used for an extended period of time (for example in winter), the
terminal must be stored in a dry place.
For mounting and repair jobs, especially for welding jobs on the machine, disconnect the
power supply to the terminal.
INFORMATION
KRONE ISOBUS systems regularly pass the ISOBUS COMPATIBILITY TEST (AEF/DLG/
VDMA test). The operation of this machine at least requires implementation level 3 of
ISOBUS system.
1
2
EQG000-024
The electronic equipment of the machine consists essentially of the job computer (1), the
terminal (2) and the control and function elements.
The job computer (1) is located on the front left of the machine under the side hood.
The driver gets information by means of the terminal (2) and settings for the operation of the
machine are performed which are gathered by the job computer and further processed.
6.1 ISOBUS Shortcut Button (ISB)
WARNING
The ISOBUS Shortcut Button is not an EMERGENCY STOP switch. If the ISOBUS
Shortcut Button is confused with the EMERGENCY STOP switch, there is danger to life.
When actuating the ISOBUS Shortcut Button, activated machine functions are deactivated.
Process oriented procedures perform to the end. Therefore machine parts can continue to run
after actuating the ISOBUS Shortcut Button. This may lead to injuries.
The ISOBUS Shortcut Button does in no case intervene in the tractor functions, i.e. neither
the universal shaft function nor the hydraulic function is affected. Therefore, the machine can
continue to run after actuating the ISOBUS Shortcut Button. This may lead to injuries.
Never use the ISOBUS Shortcut Button as an EMERGENCY STOP switch.
When actuating the ISOBUS Shortcut Button (1) of the terminal which is of the pushbutton
design, a stop command is sent to the ISOBUS. This instruction is evaluated by the connected
ISOBUS machine in order to deactivate activated machine functions. Process oriented
procedures are executed until the end. When the ISOBUS Shortcut Button is actuated, the
display shows a corresponding alarm mask:

Table of Contents

Other manuals for Krone Big Pack 890 XC

Related product manuals