Terminal – menus [Medium Plus/Comfort Plus Electronics] 9
Menu 1 "Knotter" 9.7
Supplement to Operating Instructions 150000773_00_en
BiG Pack 1270, BiG Pack 1270 XC, BiG Pack 1290, BiG Pack 1290 HDP, BiG Pack 1290 HDP XC, BiG Pack
1290 XC, BiG Pack 890, BiG Pack 890 XC
53
9.7.1 Menu 1-1 "Correction value for bale length"
Because of the different properties of materials (e.g. straw, silage) the actual bale length may
deviate from the set setpoint value. The correction value can be used to correct this deviation.
1-1
110%
90%
100%
1
EQ001-005 / EQ001-059
ü Menu 1 "Knotter" has been selected, refer to page52.
To open the menu, press
.
Æ The display shows the "Correction value for bale length" menu.
Recurring icons refer to page48.
Display area
Item Designation Explanation
(1) Correction value for bale length Adjustable value range: 90-110%
If a correction value of e.g. 110% is set, the
bale will be 10% longer.
Factory setting: 100%
Change value, refer to page51.
9.7.2 Menu 1-2 "Knotter signal"
This menu can be used to set whether an acoustic signal is to sound after a knot is tied.
1-2
1/2
EQ001-005 / EQ001-060
ü Menu 1 "Knotter" has been selected, refer to page52.
To open the menu, press
.
Æ The display shows the "Knotter signal" menu.
Recurring icons refer to page48.

Table of Contents