Terminal – menus [Medium Plus/Comfort Plus Electronics] 9
Menu 15 "Settings" 9.15
Supplement to Operating Instructions 150000773_00_en
BiG Pack 1270, BiG Pack 1270 XC, BiG Pack 1290, BiG Pack 1290 HDP, BiG Pack 1290 HDP XC, BiG Pack
1290 XC, BiG Pack 890, BiG Pack 890 XC
75
EQ001-080 / EQ001-012
ü Menu 15 "Settings" has been selected, refer to page74.
Press
to open the menu.
Æ The display shows the “Sensor Test” menu.
Icon Designation Explanation
Select previous sensor
Select next sensor
Exit menu
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be set so that the bar is within the upper
marking in the alive state. Then check whether the bar is in non-alive state in the lower marked
area.
Possible sensors (depending on the machine configuration)
An overview of the position of the sensors and actuators is in the circuit diagram, refer to
page97.
No. Sensor Designation
B1
Flywheel brake
B2
Blade cassette up
B3
Monitoring lubricant flow
B4
Baling ram at rear (measure)
B5
Baling ram at front (calibrate)
B6
Speed of packer