9 Terminal – menus [Medium Plus/Comfort Plus Electronics]
9.16 Alarm messages
88
Supplement to Operating Instructions 150000773_00_en
BiG Pack 1270, BiG Pack 1270 XC, BiG Pack 1290, BiG Pack 1290 HDP, BiG Pack 1290 HDP XC, BiG Pack
1290 XC, BiG Pack 890, BiG Pack 890 XC
Error number Designation Icon
522540-19 Timeout of the CAN messages from KMB 1
522560-19 Timeout of the CAN messages from force
measurement amplifier 1 (FMA 1)
FMI 31: The conditions of the message have been met.
Error number Designation Icon
522536-31 Error from the RMC control unit
522542-31 Error from KMB 1
9.16.1.4 General input/output error 521100 - 521299
FMI 3: There is a short circuit or an overvoltage.
Error number Designation Icon
521100-3 Voltage group(UB1)
521101-3 Voltage group(UB2)
521102-3 Voltage group(UB3)
521103-3 Voltage group(UB4)
521104-3 Voltage group(UB5)
521105-3 Voltage group(UB6)
521107-3 The power supply of the KMC at the UE
connection has an excessively high voltage.
FMI 4: There is a cable break/short circuit, general error or undervoltage.
Error number Designation Icon
521100-4 Voltage group(UB1)
521101-4 Voltage group(UB2)
521102-4 Voltage group(UB3)
521103-4 Voltage group(UB4)
521104-4 Voltage group(UB5)
521105-4 Voltage group(UB6)
521107-4 The power supply of the KMC at the UE
connection has an excessively low voltage.
FMI 5: There is a cable break, general error or overload.
Error number Designation Icon
521100-5 Voltage group(UB1)
521101-5 Voltage group(UB2)
521102-5 Voltage group(UB3)
521103-5 Voltage group(UB4)