Terminal – menus [Medium Plus/Comfort Plus Electronics] 9
Alarm messages 9.16
Supplement to Operating Instructions 150000773_00_en
BiG Pack 1270, BiG Pack 1270 XC, BiG Pack 1290, BiG Pack 1290 HDP, BiG Pack 1290 HDP XC, BiG Pack
1290 XC, BiG Pack 890, BiG Pack 890 XC
95
Error number Possible cause Remedy
522078-15 The upper limit value of the moisture
measurement has been exceeded.
Check the setting and correct if
required.
522079-17 The lower limit value of the moisture
measurement has not been reached.
Check the setting and correct if
required.
522080-2
S7
The "Switch on blade cassette"
pushbutton is sticking.
Eliminate the cause of the
pushbutton sticking.
Replace the pushbutton.
522081-2
S8
The "Switch off blade cassette"
pushbutton is sticking.
522085-13 The "Baling ram at rear" sensor is
defective.
Replace the sensor.
522086-13 The "Baling ram at front" sensor is
defective.
522087-17 The "Measure" sensor and the
"Calibrate" sensor have been
interchanged.
Swap the plugs of the "Measure"
and "Calibrate" sensors.
522088-7 "Packer feed (feeder strip)" sensor Set the sensor.
9.16.1.6 Error message from sensors 522100 – 522299
All error messages from sensors are configured according to the following sample:
e.g. error message "522101-6
B 8
"
522101 6
B 8
SPN (Suspect Parameter Number) FMI Icon
Designation Explanation
SPN (Suspect Parameter Number) Error number
FMI Indicates the type of error, refer to page85.
Icon Meaning of the icons, refer to page75
9.16.1.7 Error message from actuators 522300 – 522499