Start-up Attaching and removing the front attachment
512
15.4 Removing EasyFlow
WARNING
Risk of injury from movement of the front attachment!
If people are in the area of the front attachment when it is being raised or lowered and folded in
or out, there is a risk that these people may be caught and injured by the front attachment or
the lifting unit.
When the front attachment is moving, ensure that there is nobody in the area of the front
attachment or the lifting unit.
NOTE
Separate operating instructions for the respective front attachment are supplied, in which all
relevant work steps and safety regulations are described in detail.
Shut down and safeguard the machine, see chapter Safety -> Safety routines, "Shutting
down and safeguarding the machine".
Fig. 448
Lock the pendulum frame by moving the locking pin (1) from position "II" to position "I".
Fig. 449
Unfold the supporting wheels and lower the Pick-up to the ground.
Swivel socket pin (3) of the parking supports (4) by 180° upward on both sides and pull
them out.
Pull out the parking supports (4) and lock them with socket pins (3) in the fifth hole from
below by a rotation of 180°.
NOTE
Always insert parking supports into the fifth hole from below.