26.1.1 Maintenance of power take-off gear
Oil level check
Fig. 677
The oil level of the power take-off gear (1) must reach up to 1/2 the inspection glass (2), if
necessary top up gear oil.
Oil change
Fig. 678
Bring the machine up to operating temperature.
Thoroughly clean the area surrounding the locking cap at the drain sleeve (1) and the oil
filler plug (3).
Dismount the locking cap at the drain sleeve (1).
Provide a collecting vessel (approx. 30 litres).
Place the end of the drain hose (included with the machine) into the collecting vessel.
Mount the other end of the hose onto the drain sleeve (1). This automatically opens the
drain valve and the oil drains into the collecting vessel.
Remove the drain hose.
Mount the locking cap at the drain sleeve (1).