Info centre "EasyTouch"
277
Calibrating row tracer outer tip left/central tip right (1)
When the row tracer "Outer tip left/central tip right" is activated, the sensor value is increased.
Fig. 211
• Using the incremental encoder, choose the setting or <row tracer
left>, the input field is highlighted in colour.
• Press the incremental encoder to jump to the input field.
• Press the incremental encoder 2 times to save the current actual value of the row tracer left
and to exit the input field.
• The actual value must be in the range of 265 ±50. If necessary, readjust the sensor.
• If the row tracer actuated up to the end stop, the actual value must be in the range of
515-635.