Info centre "EasyTouch"
281
Calibration of minimum current for valve, steering to the left
• Using the incremental encoder, choose
<left valve current value> (9), the input
field is highlighted in colour.
• Press the incremental encoder to jump to the input field.
• With the incremental encoder, increase the current setpoint value (in increments of 0.01%)
of the valve until the steering just starts to move.Then reduce the setpoint value
(in increments of 0.01%), until the steering just stops moving.
• Press the incremental encoder 2 times to save the current that is currently displayed and to
exit the input field.
The saved minimum current value for the left valve
is updated.
• Press the
key beside the incremental encoder to cancel the operation.
Calibrating the minimum current for valve, steering to the right
• Move the steering axle to the straight-ahead position.
• Using the incremental encoder, choose
"right valve current value" (11), the input
field is highlighted in colour.
• Press the incremental encoder to jump to the input field.
• With the incremental encoder, increase the current setpoint value (in increments of 0.01%)
of the valve until the steering just starts to move.Then reduce the setpoint value
(in increments of 0.01%), until the steering just stops moving.
• Press the incremental encoder 2 times to save the current that is currently displayed and to
exit the input field.
The saved minimum current value for the right valve
is updated.
• Press the key beside the incremental encoder to cancel the operation.