Info centre "EasyTouch"
292
For corn conditioner with discs
Fig. 223
The current power consumption of the corn conditioner is indicated by the icon . It is
required for diagnostic purposes by the KRONE service technicians.
• The diesel engine is switched off.
• The machine is prevented from rolling away.
• Press the key to reduce the roller distance to the minimum possible distance.
• Press the key to maximise the roller distance.
• Swing out the corn conditioner, see page 453; to do so:
• Loosen the screw connection for central lubrication.
• Disconnect the plug connection of the adjusting motor.
• Remove the kraftband of the corn conditioner.
• Use the cable winch to fully lower the corn conditioner.
• Measure the distance B
[mm] between the grease nipples of the left-hand bearing housing.
• The distance of the discs is X= B [mm] – 200mm.
• Using the incremental encoder, choose the "distance" setting, the input field is highlighted in
colour.
• Press the incremental encoder to jump to the input field.
• >Use the incremental encoder to set the calculated distance X.
• Press the incremental encoder to exit the input field.
The display (1) switches to "Calibration process running" and "Calibration process
successfully completed".
• Press the menu button to access the previous menu level.
• Install the corn conditioner, see page 471.