Maintenance supply system
691
Fig. 636
Insert the new grinding stone (2) with new clamping rings from above.
Adjust the grinding stone to the previously determined dimension “b” - 2 mm.
Tension the grinding stone by using the ratchet wheel (tightening torque 180 Nm).
Pull out the detent pin (3), rotate it 90° and lock it in this position.
Mount the adjustment sheet (1).
Close the grinding unit flap protection.
Check once again if the dimension “b” is - 2 mm.
NOTICE
The grinding stone should always be higher than the chopping blade risk of collision!
Reset the grinding cycle counter in the info centre.