Maintenance supply system
703
Fig. 653
Measure the distance (a) from the counterblade (2) to the drum shell on the right and left
side of the chopping drum.
Determine the differential between the two measurements and taken into account in the
following adjustment of the counterblade (2).
Adjust the counterblade so that there is a maximum distance of a = 80-82 mm between the
counterblade (2) and the drum body.
Fig. 654
Tighten all hexagon head screws (2) using a torque wrench in the sequence 3a; 3b; 3c; 2a;
2b (tightening torque 280 Nm).
Loosen the chopping drum locking mechanism, turn the chopping drum one row of knives
further and lock again.
Re-adjust the next row of knives.
Continue in this manner until all rows of knives on the chopping drum have been re-
adjusted evenly.
Loosen the chopping drum locking mechanism.
NOTE
The grinding stone will be destroyed if it is not adjusted in line with the re-adjusted cutter
blades.
Set the grinding stone so that there is a distance of 0.5 mm between the blade back and the
grinding stone, see page 686.
Attach the feed attachment, see page 657.
Grind the chopping blades, see page 682.
Re-adjust the counterblade, see page 685.