Maintenance – supply system
705
Removing the chopping blade
Fig. 656
• Measure the distance (a) from the counterblade (2) to the drum shell on the right and left
side of the chopping drum.
• Determine the differential between the two measurements and taken into account in the
following adjustment of the counterblade (2).
• Adjust the counterblade so that there is a maximum distance of a = 80-82 mm between the
counterblade (2) and the drum body.
Abb. 657
• Unscrew the hexagonal head screws (1).
• Remove the chopping blade (2), the perforated plate (4) and the screw bar (3).
• Clean the blade carrier (5) and the screw bar (3).
• Check the screw bar (3) for damage and wear, and replace it if necessary.