Maintenance electrical system
741
Checking/tensioning/replacing V-belt of the alternator
The procedure can be found in the supplied Liebherr operating and maintenance manual.
If the three-phase generator fails or does not work properly, determine the cause of the
damage. If the suggestions below do not repair the damage, ask your KRONE dealer.
Malfunction
Cause, remedy
Charging warning light
lights up.
The output voltage of the alternator is too low
Have the alternator checked by a qualified service centre.
Error messages
Under/overvoltage.
The batteries are inadequately charged.
Charge the batteries.
The batteries are defective.
Replace the batteries (in pairs).
The connection cable to the alternator is loose.
Tighten the cable connections to the corresponding
tightening torque (see maintenance or repair
instructions).
The cable connections are corroded.
Clean the cable connections on the alternator and
battery.