Menu 2-1 Calibration of Path Sensor
Before placing the machine in service the first time and after any assembly work on the path
sensor, it must be calibrated. In this process, it must be ensured that there is no crop in the
intake and the pre-compression rollers are in the bottom position on the stop.
Fig. 80
Calling the menu
Main menu 2 “Calibration“ is called.
• Select menu 1-1 by pressing function keys or , the symbol is highlighted in
grey.
• Press function key
The display shows menu 2-1 „Calibration of Path Sensor“.
The left bar display and the value below it show the calibrated voltage value for the path sensor.
The right bar display and the value below it show the current voltage value of the path sensor. If
the red bar is the red marked area, the path sensor can be calibrated.
A calibration is not possible if the value is outside this area. The following causes may be
possible:
• The intake is soiled so that the intake rollers are not in the position on the stop.
• Path sensor defective.
• The voltage value is too small after assembly. Mount a distance sheet, if necessary.
The symbol in the upper line indicates that the calibrated value is saved.
Calibrating the path sensor
The current voltage value of the path sensor is saved as a calibrated value via function key
.