VIII - 28
KRONE operation terminal Beta
8.11.2 Menu 4-4 "Manual actuator test"
The actuator test is used to test the actuators installed
on the machine.
An actuator can only be tested if power is flowing
through it. In the manual actuator test the actuator
must therefore be controlled manually for a short time
to be able to determine if there are any errors in the
actuator system.
During the actuator test, the PTO
must not be turning.
During the actuator test, the
actuators are controlled by the
system. This may result in the
machine performing unexpected
actions. Because of this, the test must
only be performed from a safe
position outside the area that is
affected by machine parts moved by
the actuators.
Calling the menu
Main menu 4 "Service" is called.
• You can select menu 4-4 with the or
keys. The icon is shown in reverse colours.
• Press the key.
The display shows menu 4-4 "Manual actuator test".
Selecting the actuator
• Select the actuator with the or key.
The selected actuator at the left in the display is shown
in reverse colours.