V - 26
Basic Settings and Operation
5.13.1 Oil flow rate setting (cam pump)
The cam pump is located at the front left on the gearbox
drive shaft.
Adjust oil flow rate/oil pressure:
Undo bolts (2).
Rotate the excenter disk (1).
Tighten bolts (2).
1
2
3
4
5
6
7
8
128 mm
VP-2-001
1
2
2
The numbers in brackets indicate the size of the
nozzles for the individual lubrication points.
5.13.2 "Central chain lubrication" diagram
When replacing the nozzles, it is essential
to ensure that the correct sizes are used.
Each difference in size will double the oil
supply (example: MM4 will supply twice as
much oil as MM3).
COMPRIMA F125 XC / F155 XC
(2) Pick-up
(3) Netzwalze
(4) Hauptantrieb
(4) Hauptantrieb
(6) Starterwalze
(6) Starterwalze
(6) Stirnrad
(5) Schneidwerkantrieb
(5) Schneidwerkantrieb
(2) Pick-up Antrieb
(2) Pick-up
(6) Starter roller
(6) Starter roller
(6) spur wheel
(5) Cutting platform drive
(5) Cutting platform drive
(2) Pick-up drive
(2) Pick-up
(2) Pick-up
(3) Net roller
(4) Main drive
(4) Main drive

Table of Contents