EasyManua.ls Logo

Krone Comprima F 155 XC - 7.13 Menu 4 “Tying start delay” (twine tying)

Krone Comprima F 155 XC
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Terminal menus
7.13 Menu 4 "Tying start delay" (twine tying)
44
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en
n
4
1,0
0,0
0.0
s
EQG003-003
ü For The menu level is active, refer to page36.
ü For the “Net and chamber film wrapping” version: Net wrapping is selected in menu 8 “Type
of tying”, refer to page48.
To open the menu, press
.
Æ The display shows menu “Tying start delay”.
Adjusting the tying start delay
Increase or decrease the value, refer to page37.
To save the value, press
.
7.13 Menu 4 "Tying start delay" (twine tying)
The time period between completion of the round bale in the bale chamber and activation of the
tying cycle is set using the tying start delay. The tying start delay is set in seconds.
Comprima F
Setting range: 0.0–1.0s
Comprima V
Setting range: 0.0–2.5s