9.7 Adjusting the roller conditioner (optional extra/ CRI)
CRI-0-001
Figure 35:
General
The roller conditioner is supplied for use with leguminous vegetation or other leaf crops. The
conditioning intensity can be adjusted by means of screws and tension springs to change the
distance between, or the contact pressure on the rollers. The minimum distance (x) between the
rollers should always be at least 2 mm.
Pos: 22.61 /BA/Einste llungen/Mähwerke/ Rollen-Conditioner s/Einstellen de s Rollenabstandes Easy Cut @ 3\mod_1204714648695 _78.docx @ 72279 @ 2 @ 1
9.8 Adjusting the roller distance
EC-187-0
Figure 36:
The roller distance (X) can be adjusted by means of the screw (1) located at the right and the
left sides of the machine. Loosen the counter nut (2) and make the adjustment by turning the
screw (1).
Screw turned in direction 1 => distance is increased
Screw turned in direction 2 => distance is decreased
Tighten the counter nut (2) again.