Special equipment
112
Pos: 31.41 /BA/So nderausstatung /EasyCut / AM M ähwerke/Qu erförderer/Hydra ulik Ölstands kontrolle Bild EC 9 140 @ 10\mod _1222335761 098_78.doc @ 1 40606
Figure 69
Pos: 31.42 /Überschrif ten/Überschrif ten 3/K-O/Öl kontrolle @ 0\ mod_11970219 08190_78.doc @ 16120
14.10.3 Checking the oil level
Pos: 31.43 /BA/So nderausstatung /EasyCut / AM M ähwerke/Qu erförderer/Hydra ulik-Ölstandsko ntrolle @ 10\mod _122233558425 5_78.doc @ 1 40585
Check the hydraulic oil level after every 10 operating hours of the cross conveyor.
To do this:
• Lower the machine and switch off the engine.
• Unscrew and remove the ventilation filter (2) (with measuring rod).
• • Use a lint-free cloth to clean the ventilation filter (2) and insert it again completely.
• Pull out the ventilation filter (2) again.
• The oil level must lie between the min. and max. mark.
• Top off with hydraulic oil if necessary.
• Screw in and tighten the ventilation filter (2).
Pos: 31.44 /Überschrif ten/Überschrif ten 3/K-O/Öl wechsel @ 0\ mod_1197021 941955_78.doc @ 16139
14.10.4 Oil change
Pos: 31.45 /BA/So nderausstatung /EasyCut / AM M ähwerke/Qu erförderer/Hydra ulik-Ölwechsel @1 0\mod_122233 5966973_78.doc @ 140673
Change the hydraulic oil every 500 hours (but at least once a year).
• Unscrew and remove the ventilation filter (2) (with measuring rod).
• Screw out the oil drain plug (3).
• Collect the used oil in a suitable drip pan.
• Screw in the oil drain plug (3).
• Top up oil (2) (the oil level must lie between the min. and max. mark).
• Screw in and tighten the ventilation filter (2).
Pos: 31.46 /BA/--- --Seitenumbruc h------ @ 0\mo d_119617531 1226_0.doc @ 41 65