KRONE ISOBUS-Terminal CCI 100
111
Pos: 61.46.41.28 /BA/ Info-Center/CCI -ISOBUS-Terminal/CCI -BiG Pack/Hauptmenüs/ Hauptmenü 4 Service/ Diagnose Versorgungs spannungen @ 44\mod_12756 33269890_78.doc x @ 393329 @ @ 1
Diagnostics power supply voltages
4-2
U1
CC000045
Fig. 70
No. Sensor symbol Description
U1
U1
Supply voltage
Nominal voltages:
• 12V Ges: 12 - 14.5 V
• 12V Term: 12 - 14.5 V
• 12V Si: 12 – 14.5 V
• 12V ana: 12 – 14.5 V
• 8V dig: 8.5 - 9.1 V
• 12V Pow2: 12 - 14.5 V
• 12V Pow3: 12 - 14.5 V
Pos: 61.46.41.29 /BA/ Info-Center/CCI -ISOBUS-Terminal/CCI -BiG Pack/Hauptmenüs/ ESC drücken um Menü Servic e 4 zu schließen bzw. zum Grund bild zugelangen @ 44\mod_ 1275893530687_78. docx @ 393687 @ @ 1
• Pressing the function key closes the called up menu
The display shows menu level 4 "Service".
• Pressing the function key
and holding it down brings up the basic screen
Pos: 61.46.41.30 /Lay out Module /------ ---------Seitenu mbruch--------- ------- @ 0\mod_1196175311 226_0.docx @ 4165 @ @ 1