KRONE ISOBUS-Terminal CCI 100
129
Pos: 61.46.67 /Übersc hriften/Überschri ften 3/K-O/Logisc he Alarme @ 185\mod_13794191 86279_78.docx @ 1594483 @ 3 @ 1
11.9.1 Logical Alarms
Pos: 61.46.68 /BA/I nfo-Center/CCI- ISOBUS-Terminal/CCI- EasyCut/EasyCut B 1000/ Alarmmeldungen/Logi sche Alarme EC B 1000 @ 190\mod_ 1381472757103_78.doc x @ 1628094 @ @ 1
No. Image Possible cause Remedy
1
– The P.T.O. shaft is still running
when attempting to move the
mowing unit left into transport
position.
– Turn off P.T.O. shaft and wait
until it stops.
2
– The P.T.O. shaft is still running
when attempting to move the
mowing unit right into transport
position.
3
– Pressure threshold is not
reached.
– The tractor engine is OFF.
– The hydraulic block does not get
any oil.
– Start the tractor engine.
– Pressurise the control unit.
– Check the LS hydraulic system.
4
– The information appears when
folding up the machine into
transport position.
– Observe transport height.
– Make certain the side guards are
folded up.
5
– The setpoint working width right
is not reached.
– Check the parts for width shift for
damage.
– Completely retract the lateral
mowing unit once.
6
– The setpoint working width left is
not reached.
11
11
L
– The swath roller height left is not
reached.
– Check the parts for swath roller
height for damage.
12
12
R
– The swath roller height right is
not reached.
13
13
L
– Time error, the process for lifting
mowing unit left takes longer
than 30 seconds.
– The sensor setting is incorrect.
– Insufficient hydraulic supply.
– Perform a sensor test.
– Check hydraulic supply.
14
14
R
– Time error, the process for lifting
the mowing unit right takes
longer than 30 seconds.
– The sensor setting is incorrect.
– Insufficient hydraulic supply.
15
15
– Time error; the process for lifting
the front mowing unit takes
longer than 30 seconds.
– The sensor setting is incorrect.
– Insufficient hydraulic supply.