Special equipment
218
Pos: 120.30 /Überschr iften/Überschr iften 3/K-O/Ölkontro lle @ 0\mod_11970219081 90_78.docx @ 16120 @ 3 @ 1
22.7.3 Checking the oil level
Pos: 120.31 /BA/Sonderau sstatung/Easy Cut / AM Mähwerke/Querför derer/Hydraulik Öls tandskontrolle Bild EC B 100 0 CV Collect @ 101\mod_133 0684489399_78.doc x @ 899332 @ @ 1
Fig. 146
Pos: 120.32 /BA/Sonderau sstatung/Easy Cut / AM Mähwerke/Querför derer/Hydraulik- Ölstandskontrolle @ 10\ mod_1222335584255_78. docx @ 140585 @ @ 1
Check the hydraulic oil level after every 10 operating hours of the cross conveyor.
To do this:
• Lower the machine and switch off the engine.
• Unscrew and remove the ventilation filter (2) (with measuring rod).
• • Use a lint-free cloth to clean the ventilation filter (2) and insert it again completely.
• Pull out the ventilation filter (2) again.
• The oil level must lie between the min. and max. mark.
• Top off with hydraulic oil if necessary.
• Screw in and tighten the ventilation filter (2).
Pos: 120.33 /Überschr iften/Überschr iften 3/K-O/Ölwechse l @ 0\mod_1197021941955_78. docx @ 16139 @ 3 @ 1
22.7.4 Oil change
Pos: 120.34 /BA/Sonderau sstatung/EasyC ut / AM Mähwerke/Querför derer/Hydraulik- Ölwechsel @ 10\mod_122233596 6973_78.docx @ 140673 @ @ 1
Change the hydraulic oil every 500 hours (but at least once a year).
• Unscrew and remove the ventilation filter (2) (with measuring rod).
• Screw out the oil drain plug (3).
• Collect the used oil in a suitable drip pan.
• Screw in the oil drain plug (3).
• Top up oil (2) (the oil level must lie between the min. and max. mark).
• Screw in and tighten the ventilation filter (2).
Pos: 120.35 /Layout Modul e /---------- -----Seitenumbruch- ------------ --- @ 0\mod_1196175311226_0. docx @ 4165 @ @ 1