KRONE ISOBUS-Terminal CCI 100
52
Pos: 61.18 /BA/Inf o-Center/CCI-I SOBUS-Terminal/Terminal ansc hließen (ohne ISO Schle pper) @ 43\mod_12748822 31640_78.docx @ 387925 @ 3 @ 1
8.2.4 Connecting the terminal (on tractors without ISOBUS system)
Fig. 26
Connection terminal to machine
Note
The connection of terminal to machine takes place via a provided cable set (5) (article no.
20 081 224 0).
Connect plug (2) of cable set (5) with socket (1) (CAN1-IN) of the terminal
Connect plug (6) (7-pole) of cable set (5) with socket (7) (7-pole) of the machine
Connect connector plug (4) (article no. 00 302 300 0 included in scope of delivery) with
socket (3) (CAN1-OUT) of the terminal
Connection tractor to machine
Note
The connection of tractor to machine takes place via a provided power cable (8) (article no.
20 080 601 0).
Connect plug (9) of power cable (8) with continuous current socket (10) of the tractor
Connect plug (11) (2-pole) of power cable (8) with socket (12) (2-pole) of the machine