6 Initial Operation
6.3 Adapting coupling points
36 Original Operating Instructions 150000802_00_en
Conversion to category III
Pull out the lower link pins (2).
Turn the lower link pins (2) by 180° and insert them through the ball sleeves cat. III (3).
Secure the lower link pins (2) by means of the linch pin (4) and the safety chain (5).
The longer journal of the lower link pin (2) faces inwards.
Top link pin
The top link pin (1) is designed for category II and III.
KM000-351
Category II (cat. II)
Loosen the linch pin (3) and pull out the top link pin (1).
Insert the top link pin (1) in the position (I) or (II) and through the ball sleeve cat. II (2).
The thicker journal of the top link pin (1) is facing outwards.
Secure the top link pin with the linch pin (3).
Make sure that the anti-twist lock (4) of the top link pin is in the recess.
Category III (cat. III)
Insert the top link pin (1) in the position (I) or (II) and through the ball sleeve cat. III (2).
The thinner journal of the top link pin (1) is facing outwards.
Secure the top link pin with the linch pin (3).
Make sure that the anti-twist lock (4) of the top link pin is in the recess.