EasyManua.ls Logo

Krone Swadro 1000 - Malfunctions - Causes and Remedies

Krone Swadro 1000
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Medium Control Unit
43
Pos: 21.39 /Übersc hriften/Überschrif ten 2/P-T/Stör ungen - Ursa chen und Beheb ung @ 2\mod _12033258260 11_78.docx @ 65688 @ 2 @ 1
6.15 Malfunctions - Causes and Remedies
Pos: 21.40 /BA/I nfo-Center/Schw ader/Bedienein heit- M edium/ Swadro 1000/Stör ungen_Ursach e_Behebung @ 2\mod_12033 25023621_78.d ocx @ 6566 9@ @ 1
No. Description Possible cause Remedy
11 Over/under
voltage
Tractor battery defective Check battery
Tractor dynamo defective/too weak. Check dynamo
12-V power supply too weak on the tractor
side or not correctly connected with the
battery.
Connect the KRONE connection cable to
the tractor battery
13 CAN error The CAN bus was interrupted between
the control unit and the machine > loose
connection to display screen.
Check the display line.
14 Incorrect
terminal
Connection to incorrect terminal. Use the terminal appropriate to the
swather type.
15 Incorrect
terminal
software
Terminal software and job computer not
compatible
Use correct software.
16 Control unit key
defective
Key sticks when turned on. Check keys.
21 Sensor error Broken cable / short circuit in a sensor. Check sensors
Pos: 21.41 /BA/--- ------ ------Seitenumbruch---- ------------ @ 0\m od_1196175311 226_0.docx @ 4 165 @ @ 1