Do you have a question about the KRUEGER KQFP and is the answer not in the manual?
Overview of units, VAV capability, and heating options.
Standard airflow sensors and available control options.
Guidelines for inspecting, storing, and handling units to prevent damage.
Instructions for selecting location, positioning, and installing the fan-powered box.
Guidance on unit suspension methods using field-supplied supports.
Checks for air handlers and system components before balancing.
Information on setting maximum and minimum airflow set points and fan speed adjustment.
Procedures for adjusting airflow set points using the airflow sensor and chart.
Checks to be performed on air handlers and system components before balancing.
Critical steps for proper unit operation and service, including power disconnection.
Procedures for balancing series flow units by setting fan and VAV damper flow.
Steps to set fan airflow, including disabling heat and checking fan direction.
Setting minimum and maximum airflow levels for pneumatic or electronic controllers.
Procedures for adjusting airflow set points using the airflow sensor and chart.
Steps to set fan airflow, including disabling heat and checking fan direction.
Procedures for setting VAV airflow, including adjusting set points and measuring flow.
Setting minimum and maximum airflow levels for parallel fan units.
Instructions to increase fan speed by turning the adjustment knob clockwise.
Instructions to decrease fan speed by turning the adjustment knob clockwise.
Operating manual speed control units using the ECM controller and adjustment knob.
Using a 0-10Vdc signal to control airflow between 0% and 100%.
Using a 2-10Vdc signal for on/off control and airflow adjustment.
General information on pneumatic controls and their installation.
Procedures for balancing units with single-function pneumatic controllers.
Procedures for balancing units with multi-function pneumatic controllers.
How the unit operates under different thermostat demands for pneumatic controls.
Steps for installing and balancing the Analog Electronic Control System.
Guidelines for mounting the thermostat to ensure proper temperature sensing.
Instructions for selecting sequences and setting airflow limits on the thermostat.
Checks for controller shaft, wiring, power supply, and jumper position.
Troubleshooting incorrect rotation direction or stroke range.
Steps to check wiring, tubing, sensor orientation, and air flow for signal issues.
Checks for clearance issues, ductwork integrity, and fan speed for noise problems.
Steps to diagnose why the fan motor is not running, checking power, signals, and rotation.
Procedures for removing, servicing, and reassembling the fan motor and wheel.