Charge flow
1.
Power from the crankshaft turns the fan drive pulley
.
2. Power is transferred to the alternator via the fan belt.
3. Rotation of the alternator pulley causes the alternator to rotate generating power.
4. The generated electricity is supplied to and charges the battery via the B terminal of the alternator.
MECHANISM
8. Electrical system 4. ENGINE
D1803-CR-E4,D1803-CR-TE4,D1803-CR-TIE4,V2403-CR-E4,V2403-CR-TE4,V2403-CR-TE4BG,V2403-CR-TIE4
4-69