(17) Fuel Pump Relay Control/Coil (DTC 627 to 629)
DTC 627-Fuel Pump Relay Coil Open
Hardware: Fuel Pump Relay Pull in Coil
Enabling Conditions: Key On
Set Conditions: Fuel Pump relay coil output open circuit for more than 10 samples of the circuit
Corrective Action(s): Illuminate MIL
Non-emissions related fault
Possible Causes: Open coil in relay, Open in relay driver circuit in engine harness or faulty ECM
DTC 628-Fuel Pump Relay Ground Short
J1939 SPN: 1348 FMI: 4
Hardware: Fuel Pump Relay Pull in Coil
Enabling Conditions: Engine Running
Set Conditions: Fuel Pump relay coil output shorted to ground for more than 10 samples of the circuit
Corrective Action(s): Illuminate MIL
Non-emissions related fault
Possible Causes: Relay pull in coil shorted internally, relay driver circuit shorted to ground in wire harness, faulty
ECM
J1939 SPN: 1347 FMI: 5
Hardware: Fuel Pump Motor
Enabling Conditions: Engine Running
Set Conditions: Fuel pump motor high-side on-state < 4.0 volts, battery voltage > 8.0 volts
Corrective Action(s): Illuminate MIL
Non-emissions related
Possible Causes: