(18) 5 V External (DTC 642, 643, 652, 653, 1611)
DTC 642-Sensor Supply Voltage 1 Low (5 Vext1)
Hardware: External Sensor Supply Voltage Regulator 1
Enabling Conditions: Key On, Engine Off or Running
Fault Condition- Voltage feedback on sensor supply circuit #1 below 4.60 V for longer than 1 second
Corrective Action(s)- Illuminate MIL and disable fuel adaptive learn while code is active
Non-emissions related fault
Possible Causes: Internal short to ground in any sensor fed by 5 Vext1 supply, 5 Vext1 shorted to ground in wire
harness, faulty ECM (no 5 V output on 5 Vext1)
DTC 643-Sensor Supply Voltage 1 High (5 Vext1)
Hardware: External Sensor Supply Voltage Regulator 1
Enabling Conditions: Key On, Engine Off and Running
Set Conditions: Voltage feedback on sensor supply circuit #1 is greater than 5.40 V for longer than 1 second
Corrective Action(s): Illuminate MIL and disable fuel adaptive learn while code is active
Non-emissions related fault
Possible Causes: 5 Vext1 circuit shorted to 12.0 V in wire harness
DTC 652-Sensor Supply Voltage 2 Low (5 Vext2)
Hardware: External Sensor Supply Voltage Regulator 2
Enabling Conditions: Key On, Engine Off or Running
Fault Condition- Voltage feedback on sensor supply circuit #2 below 4.60 V for longer than 1 second
Corrective Action(s)- Illuminate MIL and disable fuel adaptive learn while code is active
Non-emissions related fault
Possible Causes: Internal short to ground in any sensor fed by 5 Vext2 supply, 5 Vext2 shorted to ground in wire
harness, faulty ECM (no 5 V output on 5 Vext2)
DTC 653-Sensor Supply Voltage 2 High (5 Vext2)
Hardware: External Sensor Supply Voltage Regulator 2
Enabling Conditions: Key On, Engine Off and Running
Set Conditions: Voltage feedback on sensor supply circuit #2 is greater than 5.40 V for longer than 1 second
Corrective Action(s): Illuminate MIL and disable fuel adaptive learn while code is active
Non-emissions related fault
Possible Causes: 5 Vext2 circuit shorted to 12.0 V in wire harness