Kubota WG1605-E3 - DTC 1121-FPP1;2 Simultaneous Voltages Out-Of-Range; DTC 2121-FPP1 Lower than FPP2; FPP (Foot Pedal Position Switch) (DTC 1121, 2121, 2126, 2122, 2123, 2127, 2128)

Kubota WG1605-E3
241 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ECM SYSTEM
WG1605-G-E3,WG1605-L-E3,WG1605-GL-E3, DM
1-220
(22) FPP (Foot Pedal Position Switch) (DTC 1121, 2121, 2126, 2122, 2123, 2127,
2128)
DTC 1121-FPP1/2 Simultaneous Voltages Out-of-Range
Hardware: Foot Pedal Position/Throttle control sensor
Enabling Conditions: Key On, Engine Off
Set Conditions: FPP voltage is higher than 4.80 V or lower than 0.20 V, and FPP voltage is higher than 4.80 V or
lower than 0.20 V for longer than 0.5 second
Corrective Action(s): Illuminate MIL, Power derate 2, Low rev limit, Forced idle
Non-emissions related fault
Possible Causes:
This fault is only applicable with sensors that incorporate dual potentiometer and indicates that FPP1 and FPP2
voltages are out-of-range resulting in a loss of redundancy.
DTC 2121-FPP1 Lower Than FPP2
Hardware: Foot Pedal Position /Throttle control sensor
Enabling Conditions: Key On, Engine Off
Set Conditions: (FPP1 % - FPP2 %) is lower than -20 for longer than 1.5 seconds
Corrective Action(s): Illuminate MIL, Power derate 2, Low rev limit
Non-emissions related fault
Possible Causes:
This fault indicates that the measured % deflection of sensor 1 is less than sensor 2 by an amount defined in
calibration.
KiSC issued 12, 2016 A

Table of Contents