1-5
[2] Cooling air requirements (At 25 deg.C and 1000 hPa)
NOTE
Above data is decided by following conditions.
Using the standard radiator.
Engine is run as open unit.
Model Fuel Output
Engine Speed (min
-1
(rpm))
2000 2400 2800 3200 3600
WG752
Gasoline Cooling air requirements
L/sec 359.4 418.8 476.5 550.6 651.3
m
3
/h 1294 1508 1715 1982 2345
in
3
/sec 21933 25554 29078 33598 39742
ft
3
/min 761.5 887.2 1009.5 1166.5 1379.8
LPG Cooling air requirements
L/sec 349.2 413.8 477.6 548.6 672.0
m
3
/h 1257 1490 1719 1975 2419
in
3
/sec 21307 25251 29146 33475 41005
ft
3
/min 739.7 876.7 1011.9 1162.2 1423.6
Model Fuel Output
Engine Speed (min
-1
(rpm))
2000 2400 2800 3200 3600
WG972
Gasoline Cooling air requirements
L/sec 571.2 737.2 824.7 833.9 764.8
m
3
/h 2056 2654 2969 3002 2753
in
3
/sec 34859 44988 50328 50886 46668
ft
3
/min 1210 1562 1747 1767 1620
LPG Cooling air requirements
L/sec 469.8 586.7 686.6 734.2 722.3
m
3
/h 1691 2112 2472 2643 2600
in
3
/sec 28668 35800 41896 44806 44077
ft
3
/min 995 1243 1455 1556 1530
DG972 NG Cooling air requirements
L/sec 420.6 518.3 600.2 633.0 577.9
m
3
/h 1514 1866 2161 2279 2080
in
3
/sec 25668 31628 36625 38630 35264
ft
3
/min 891 1098 1272 1341 1224