The
ADC
readings should be approximately the same
as
for the.
Master Tune
slider:
14 SLIDER
IN
DOWN
POSITION
80 SLIDER
IN
CENTER POSITION
ED
SLIDER
IN
UP
POSITION
Press
SELECT
to
proceed
to
the next
ADC
test.
LEFT
MOD
LEVER? Press
YES
The Mod Lever ADC reading may vary since final calibration
is
performed during
an
audio test. The approximate readings should be:
80
MOD
LEVER CENTERED
OA
MOD
LEVER
DOWN
EB
MOD
LEVER UP
Press
SELECT
to
proceed
to
the next
ADC
test.
RGT
MOD
LEVER? Press
YES
The
Mod
Lever ADC reading may vary since final calibration
is
performed during
an
audio test. The approximate readings should be:
80
MOD
LEVER CENTERED
OA
MOD
LEVER
DOWN
EB
MOD
LEVER
UP
Press
SELECT
to
proceed
to
the next
ADC
test.
The
POD
foot pedals have three positions:
52
PEDAL
UP
78
PEDAL HALF WAY
DOWN
A9 PEDAL
DOWN
Kurzwell 250 Service Manual, Chapter 4