5.4 - MOD LEVERS
5.4.1 -
Accessing
the
Mod
Levers
The Mod Levers are mounted
urider' the top enclosure and are
connected
to
the Slider board
on
the Front Panel assembly by a cable.
Follow
the previously described procedure for disconnecting
the top and bottom enclosure. The
Mod
Levers are held by the shafts
of their rotary potentiometers. The potentiometers are
held
in
place
by a single nut with a' lock and play washer.
5.4.2 -
Removing
the
Mod Lever
Pots
To
remove the Mod Lever pots, it will require a thin 1/2 inch
open end wrench. A positioning tab keeps the potentiometers from
rotating. This
tap
is
aligned with a hole
in
the side of the enclosure
rib where
the
pot is mounted.
Figure
5.3
Kurzwell 250 Service Manual, Chapter 5