Note:
The Enhanced Resident Sound Block caf! only be
installed in units with Ve,rsion
3.1
or better. Therefore
units that currently have Version' 2 or 2.2 must be updated
when ordering the Enhanced Resident
Sound Block.
Note:
When installing the Enhanced Resident Sound Block
in
units with sampling,
be
sure to remove the 20 DRAMs from
the old
CGP and reinstall them
in
the Enhanced Sound Block.
If the unit has a Sound Block A board with the 10 Sound
Block A chips socketed, the chips may be removed and
installed in' the Enhanced Resident Sound Block (see
Enhanced Resident
Sound Block Configuration list).
2.14.6 -
Version 5
Sound Block A
Sound Block B (Rock Block)
Sound Block C (Classical Block)
Sound Block 0 (Brass Block)
Enhanced Resident
Sound Block
50kHz
Sound Modeling Program
Ram
Sequencer Expansion
(8K)
QLS
(Quick Load System)
MacAttach
Superam I or Superam
II
Separate Outputs
-optional*
-optional*
-optional*
-optional*
-optional*
-required**
-optional***
-optional
-optional
*Units with
Sound Block A boards may have either Sound
Block
B,
C or 0 added. Should a customer desire
to
add Sound
Block
B,
C or 0 the customer would have to have the
Enhanced Resident
Sound Block installed as there
is
only
room for one additional sound block
to
the Sound Block A
board.
**The
Ram
Sequencer Expansion bringing the unit from a 4K
sequencer memory
to
8K
sequencer memory is required with
the installation of Version 3.1; because version
3.1
brings
the sequencer memory
to
12K.
***QLS may only
be
installed
in
units with sampling.
Kurzwell
250
Service Manual, Chapter 2
2 - 1 7