4.1
- INTRODUCTION TO DIAGNOSTICS
Revision B Diagnostic EPROMs are for use with Kurzweil 250
and Kurzweil 250X units with Vergion· 2.2
or
earlier software
installed. If the instrument you are testing has software later than
Version 2.2
installed, you should test it with Revision D Diagnostics.
Revision B Diagnostic EPROMs are
in
128K EPROMs. If you are
testing a Kurzweil 250X, you will need Revision B Diagnostic EPROMs
in
256K
EPROM.
4.2 - INSTALLING DIAGNOSTIC EPROMS
1.
Turn off system power
2.
Open
the slide chassis.
3.
Remove U38 and U54 from the CPU board. Be careful
when removing these EPROMs as you will be reinstalling
them when the testing is complete.
4.
Install U38 (Loc.
01)
and U54 (Loc.
02)
Diagnostic EPROMs
in
the empty sockets
on
the
CPU
board.
NOTE: When installing the diagnostic EPROMs, be sure
pin
1
is
facing the rear panel.
5.
Turn
on
system power
NOTE:
When the system is first turned on, the front panel
LEOs
may come
on
in
an
unpredictable pattern. They should
all turn off after about one second.
6.
The red power indicator light
on
the
POD
should
be
on. The
front panel
LCD
should indicate:
K250 DIAGNOSTICS (C)
REV.
B 24-JAN-85
The
SELECT switch
LED
should
be
blinking
on
and
off.
Kurzwell
250
Service Manual, Chapter 4
4-2
r
I