Press SELECT to proceed
to
the next
ADC
test.
VOLTAGE MAX? Press YES
The ADC reading should be E Q the same as the Master Tune
rightmost position.
Press
SELECT
to
proceed to next ADC test.
VOLTAGE MIN? Press YES
The ADC reading should be 14 the same as the Master Tune
leftmost position.
Press
SELECT
to
proceed
to
the
next
ADC
test.
EXTERNAL
PED
21 Press
YES
The
ADC
readings should
be
approximately the same
as
for the
External
Pedal 1:
00
PEDAL NOT PLUGGED INTO
REAR
PANEL JACK
7E
PEDAL UP
OB
PEDAL
DOWN
Press
SELECT
to
proceed
to
the
next
ADC
test.
ASSIGNABLE 3? Press
YES
The
ADC
readings should
be
approximately the same
as
for the
Master Tune
slider:
14
SLIDER
IN
DOWN
POSITION
80
SLIDER
IN
CENTER POSITION
ED
SLIDER
IN
UP
POSITION
Press
SELECT
to
proceed
to
the
next
ADC
test.
ASSIGNABLE
21
Press
YES
,
Kurzwell 250 Service Manual, Chapter 4