Specifications
Electrical Specifications
13-3
Environmental Specifications
Temperature ranges
For operation: minimum 41
°
F (5
°
C)
maximum 104
°
F (40
°
C)
For storage: minimum -13
°
F (-25
°
C)
maximum 186
°
F (85
°
C)
Relative humidity ranges (non-condensing)
Operation and storage: 5—95%
Physical Specifications
Overall dimensions
K2500R K2500 K2500X
Width 16.9 in.* 43 cm. 47.8 in. 121.4 cm. 54.3 in. 137.9 cm.
Depth 13.9 in. 35.4 cm. 17.8 in. 45.1 cm. 17.8 in. 45.1 cm.
Height 5.1 in. 13 cm. 4.8 in. 12.2 cm. 4.8 in. 12.2 cm.
Weight: 24.65 lb. 11.2 kg. 55.5 lb. 25.2 kg. 72 lb. 32.7 kg.
* Excluding the rack-mount brackets
Electrical Specifications
AC supply: selectable; 100V, 120V, 220V, or 240V. 1.0 amps at 120 volts nominal
Safe voltage ranges
Voltage setting: 100V 120V 220V 240V
Safe voltage range: 85—107 95—125 180—232 190—250
Safe frequency range: 48—65 48—65 48—65 48—65
If the voltage drops below the minimum safe level at any voltage setting, the K2500 will reset,
but no data will be lost. If the voltage exceeds the maximum safe level, the K2500 may overheat.