Multi Edit Mode
Controls Page
5-28
Scale
Use the Scale parameter to change the range of CC values sent by the controller (in
combination with the Add and Curve parameters). e Scale parameter multiplies the CC
values sent, changing the lowest and highest values sent by the controller. MIDI controllers
are limited to sending values from 0-127, even if the Scale and Add parameters are set to
produce values outside of this range.
By default, each continuous controller sends CC values 0-127, 0 at its lowest position, and
127 at its highest position. ese values can be multiplied by the percent value of the Scale
parameter in order to change the range of CC values. For example:
When when Scale is set to 100% (with Add set to 0 and Curve set to Linear), the controller
sends CC values 0-127, 0 at its lowest position, and 127 at its highest position.
Scale values 1-99% make the controller send a smaller range of CC values, allowing for ner
control of CC values. When Scale is set to 50% (with Add set to 0 and Curve set to Linear),
the controller sends CC values 0-63, 0 at its lowest position, and 63 at its highest position.
Scale values 101-300% make the controller send a values 0-127 over a smaller range of
controller positions, allowing for coarser control of CC values. When Scale is set to 200%
(with Add set to 0 and Curve set to Linear), the controller sends CC values 0-127, 0 at its
lowest position, and 127 at its middle position through its highest position.
When Scale is set to a negative number, the controller range is reversed. For example, when
Scale is set to -100% (with Add set to 0 and Curve set to Linear), the controller sends CC
values 127-0, 127 at its lowest position, and 0 at its highest position.
Add
Use the Add parameter to change the range of CC values sent by the controller (in
combination with the Scale and Curve parameters). e Add parameter adds or subtracts
from the CC values sent, changing the lowest and highest values sent by the controller. MIDI
controllers are limited to sending values from 0-127, even if the Scale and Add parameters
are set to produce values outside of this range.
By default, each continuous controller sends CC values 0-127, 0 at its lowest position, and
127 at its highest position. ese values can be added to the value of the Add parameter in
order to change the range of CC values. For example:
When when Add is set to 0 (with Scale set to 100% and Curve set to Linear), the controller
sends CC values 0-127, 0 at its lowest position, and 127 at its highest position.
When when Add is set to 64 (with Scale set to 100% and Curve set to Linear), the controller
sends CC values 64-127, 64 at its lowest position, and 127 at its middle position through its
highest position.