Chapter
2
Diagnostics
Scanner
Test
This
test
confirms
scanner
communications
by
sending
data
to
the
scanner.
After
processing
the
data,
the
scanner
sends
a
result
back
to
the
main
processor.
If
the
returned
value
is
not
as
expected
or
the
scanner
does
not
reply
as
expected,
the
test
fails.
Failure
of
this
test
indicates
a
failure
of
the
main
processor
(68301,
U21),
the
scanner
(37451,
U17)
or
traces
linking
the
two
serial
ports
of
these
devices.
There
are
no
other
components
involved
in
the
test.
Note
that
failed
scanner
communications
will
likely
disable
operating
the
diagnostics
from
the
control
panel,
since
control
panel
signals
must
be
read
and
written
through
the
scanner.
Parallel
I/O
(PI/O)
Test
The
Parallel
I/O
Test
writes
each
of
two
complementary
bit
patterns
to
bits
0-7
of
the
68301's
parallel
port,
verifying
that
the
pins
were
able
to
change
to
the
desired
state.
Failure
of
this
test
could
be
caused
by
the
main
processor
or
the
circuitry
connected
to
the
parallel
port.
Timer
Test
The
Timer
Test
confirms
the
operation
of
the
68301's
internal
timers.
Failure
of
this
test
is
caused
by
a
damaged
68301.
PC88
Service
Manual
2-9