2NC/2NF/2NG/2NN/3P7/3P8/3P9
1-5-60
9. Remove the electric wire cover by
releasing the lock lever.
10. Remove the developer electric wire
connector.
Figure 1-5-102
11. Remove the screw and then pull the
developer evacuation lever forward.
12. Remove the developer unit from main
unit by pulling forward.
Figure 1-5-103
Lock lever
Electric wire cover
Developer
electric wire connector
Hook
Developer
evacuation lever