4-29
FS-1800/1800N | FS-3800/3800N
Eraser lamp control circuit
CPU (U201) turns on its #59 pin to H and turns Q215 and Q214 on. Current flows through Q214
and R249, then the eraser lamp, activating the lamp. Current also routes through R251 and R252 as
bled by R251. Point A below is approximately 14.5 V when the eraser lamp is normal. If the eraser
lamp blows out or the connector is not fitted, current goes through only R251 and R252, subsequently
the potential at point A is as high as approximately 24 V. Difference in the potential at point A
where the eraser lamp is normal or not is automatically detected as an error. When anomaly is
detected with the eraser lamp, the detector circuit turns Q216 on and turns ERDEAD* at #60 pin of
CPU (U201) to L. This in turn causes CPU (U201) to determine that the eraser lamp is faulty,
displaying Call service personE5.
R251
R249
GND
GND
GND
1
2
2
9
3
Q214
2
2
3
3
1
1
R252
Q216
Q215
ERASE
+24V
ERASEDR
Eraser lamp [board]
YC203
P40/SCK0
ERDEAD*
P37/SOT0CLK
60
59
CPU
U201
ERASER
Engine board
Eraser lamp cotrol circuit
+5V
Drum board
A
Figure 4-3-7 Eraser lamp control circuit