6-17
FS-1800/1800N | FS-3800/3800N
(13) E1 Main motor error
Meaning Suggested causes Corrective action
The main motor is
overloaded.
Overcurrent in the main motor circuitry due
to an excessive torque.
Connector insertion error.
Defective gate array U204 on the engine
board (KP-864).
Defective harness between engine board and
engine relay board (KP-760).
Defective harness between engine relay board
(KP-760) and main motor.
Follow the flow chart
below.
Print status page.
Yes
Yes
No
No
Replace engine board
(KP-864). See page 5-22.
Does pin
#7 (MMOTRDY*)
of YC802 on engine board
goes low, after pin #3
(MMOTON*) of
YC802 goes
low?
Call service
personE1:0123456
Yes
Yes
No
No
Replace harness (S02405)
between engine board
(KP-864) and engine
relaly board (KP-760).
Replace engine relay board
(KP-760). See page 5-15.
OK?
Remove and check
harness (S02405)
between engine board
(KP-864) and engine
relaly board (KP-760),
or harness (S02401)
between engine board
(KP864) and main
motor.
+24 V DC
at #1 pin of YC802
on engine board
(KP-864) ?
Does
pin #3 (MMOTON*)
of YC802 on engine board
(KP-864) goes high,
then low?
Print status page.
Turn power switch off.
Turn power switch on.
Harness (S02401) between engine
relay board (KP-760) and engine
board (KP-864)
Replace Main motor.
See page 5-27.
Drive unit (See page 5-27.)
Engine board (KP-864) and main
motor (replace at the same time)
NOTE:
If the problem is not solved by this flow
chart replace the following items:

Table of Contents

Other manuals for Kyocera FS-1800