FS-6020
1-5-25
(16)Image becomes
dim.
(15)Fixing is poor. Causes
1. Wrong type of paper.
2. Defective fixing pressure spring.
3. Flawed press roller.
4. Defective fixing heater lamp.
Causes Check procedures/corrective measures
1. Wrong type of paper. Check to see if the paper meets the specifications.
2. Defective fixing pressure spring. Replace the fixing pressure spring.
3. Flawed press roller. Replace the press roller. (See page 1-6-22.)
4. Defective fixing heater lamp. Replace the fixing heater lamp. (See page 1-6-19.)
Causes
1. Condensation on drum.
Causes Check procedures/corrective measures
1. Condensation on drum. Perform drum surface refreshing. (See page 1-4-6.)
(17)Image is inclined.
Causes
1. Defective laser scanner unit installation.
Causes Check procedures/corrective measures
1. Defective laser scanner unit installation.
Reinstall the laser scanner unit. (See page 1-6-15.)