FS-6020
1-6-11
(4) Detaching and refitting the MP tray feed unit
Perform the following procedure when the MP tray feed unit is to be checked or replaced.
Procedure
1. Remove the top cover (see page 1-6-2).
2. Remove the left cover (see page 1-6-3).
3. Remove the right cover (see page 1-6-4).
4. Remove the MP tray feed roller (see page 1-
6-10).
5. Remove the stop ring.
Figure 1-6-11
6. Remove the hook of ground spring.
7. While opening the claw, remove the MP tray
feed pulley.
8. Remove one bush.
Figure 1-6-12
Stop ring
Ground spring
Bush
MP tray feed pulley
Claw