2MW/2MX
1-3-41
U101 Setting the voltage for the primary transfer
Description
Sets the control voltage for the primary transfer.
Purpose
To change the setting when any density problems, such as too dark or light, occur.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting value using the cursor left/right keys or numeric keys.
Increasing the setting makes the transfer voltage higher, and decreasing it makes the voltage
lower.
large sizes:(more than 220 mm wide),
medium sizes (more than 170 to under 220 mm wide),small sizes: (under 170 mm wide)
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Setting range Initial
setting
On Timing Transfer bias ON timing
-1000 to 1000 0
Off Timing Transfer bias OFF timing
-1000 to 1000 0
Pre On Timing Transfer bias Pre ON timing
-1000 to 1000 0
Pre Bias Pre Transfer bias
0 to 2000 0
Rev Bias Rev Transfer bias
0 to 2000 190
Bias(L) Transfer bias for large sizes
0 to 2000 650
Bias(M) Transfer bias for medium sizes
0 to 2000 900
Bias(S) Transfer bias for small sizes
0 to 2000 1100
Bias Half(L) Half Transfer bias for large sizes
0 to 2000 450
Bias Half(M) Half Transfer bias for medium sizes
0 to 2000 650
Bias Half(S) Half Transfer bias for small sizes
0 to 2000 750