EasyManua.ls Logo

Kyocera FS-6525MFP - Checking;Clearing the Transfer Count; Displaying the Temperature and Humidity Outside the Machine

Kyocera FS-6525MFP
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2MW/2MX
1-3-44
U127 Checking/clearing the transfer count
Description
Displays and clears the counts of the transfer counter.
Purpose
To check the count after replacement of the transfer roller. Also to clear the counts after replacing
transfer roller.
Method
1. Press the start key. The current counts of the transfer counter is displayed.
Clearing
1. Select [Clear].
2. Press the start key. The counter value is cleared.
Setting
1. Change the counter value using the cursor left/right keys or numeric keys.
2. Press the start key. The counter value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U139
Displaying the temperature and humidity outside the machine
Description
Displays the detected temperature and humidity outside the machine.
Purpose
To check the temperature and humidity outside the machine.
Method
1. Press the start key. The detected temperature and humidity are displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Cnt Transfer counter value
Display Description
External Temp External temperature (C)
External Humidity External humidity (g/m