2MN/2N1
2-3-47
Connector Pin Signal I/O Voltage Description
YC1
1 GND - - Ground
Connected to
engine PWB
2 REG_F_LED I Analog IDS1 control signal
3 REG_SENS_F_P O Analog IDS1 detection signal
4 REG_SENS_F_S O Analog IDS1 detection signal
5 GND - - Ground
6 REG_R_LED I Analog IDS2 control signal
7 REG_SENS_RP(
BK)
O Analog IDS2 detection signal
8 REG_SENS_RS(
BK)
O Analog IDS2 detection signal
9 CLN_SOL_REM I 0/24 V DC CLSOL: On/Off (ACT)
10 CLN_SOL_RET I 0/24 V DC CLSOL: On/Off (RET)
11 GND - - Ground
12 BELT_JAM_SENS - - Not used
13 DU_SENS O 0/3.3 V DC DUS2: On/Off
14 PRESS_RLS_SE
NS
O 0/3.3 V DC TRRS: On/Off
15 PRESS_MOT_RE
M2
I 0/24 V DC TRRM: On/Off
16 PRESS_MOT_RE
M1
I 0/24 V DC TRRM: On/Off
17 DU_FAN - - Not used
18 DU_OPEN O 0/3.3 V DC DUCSW: On/Off
19 GND - - Ground
20 DU2_REM(CL_L
OW)
I 0/3.3 V DC DUM2/DUCL2: On/Off
21 DU2_CLK I 0/3.3 V DC (pulse) DUM2 clock signal
22 DU2_PD I 0/3.3 V DC DUM2 control signal
23 INTER_LOCK - - Not used
24 GND - - Not used
25 GND - - Not used
26 GND - - Not used
27 GND - - Not used
28 GND - - Ground
29 MPF_LIFT1 I 0/24 V DC MPLM: On/Off
30 MPF_LIF2 I 0/24 V DC MPLM: On/Off
31 MPF_CL I 0/24 V DC MPPFCL: On/Off
32 MPF_JAM O 0/3.3 V DC MPFS: On/Off

Table of Contents